When your furnace shuts off, check the temperature on the thermostat. If the temperature is still below the setting and the furnace starts up again a few minutes later, the heating cycle could be getting cut short. That’s just one reason the furnace could run without heating your house evenly.
Our team at Jack Lehr Heating, Cooling & Electric has a few tips on what you can safely check before calling for service.
Furnace Short Cycling and Weak Airflow
Short cycling is when your heater keeps stopping and restarting before the thermostat reaches the setting you want. Your furnace may not run long enough to warm the whole house. Restricted airflow can cause your furnace to overheat and shut off the heat as a safety measure. A clogged filter is one possibility. If the filter is clean and the furnace still keeps cutting out, call us for furnace service right away.
Thermostat Settings and Location
If the furnace tends to shut off around the same time each day, the thermostat schedule could explain why. Make sure the thermostat is set to Heat, then check whether it’s programmed to lower the temperature around the time the furnace shuts off. Direct sun or a nearby lamp can warm the thermostat and cause it to shut the furnace off too soon. If the temperature difference is worse on sunny days, see whether sunlight reaches the thermostat around the time the furnace shuts off.
Dirty Furnace Filters and Blocked Vents
A clogged filter can cut airflow at several vents at once. If you notice less air coming out than usual, start there. If the filter is disposable and clogged with dust, check the furnace manual for how to shut off the unit and which replacement filter to use. It’s easy to check the vents that blow warm air and miss the larger grilles that pull air back to the furnace. Open any closed supply vents and move rugs or furniture covering them. A couch pushed against a return grille can restrict airflow, too.
Sometimes closed doors and blocked off hallways can cause disruptions in airflow, but vents are the first priority when trying to ensure your home is being equally heated.
Leaky or Disconnected Ductwork
You can have a vent wide open and still barely feel any air coming out. A loose connection can let warm air escape before it reaches the vent. A kink in a flexible duct can slow the air down, too. If you had trouble cooling that area last summer, mention it when you call. Your furnace and central AC may use the same ducts, so one leak or kink can cause trouble in both seasons.
Furnace Repair in Allentown, PA
The next time the furnace shuts off, take a look at the thermostat. If it’s set to 70 but still reads 65, tell us that when you call. We’ll check what’s stopping the furnace from heating evenly and explain what needs to be fixed.
Contact us at Jack Lehr Heating, Cooling & Electric to schedule furnace service in Allentown.